6-1750 (1997): Difference between revisions

From Rockland Apparatus
Jump to navigation Jump to search
Other Admin (talk | contribs)
m Text replacement - "| foam_capacity =" to "| foam_capacity ="
Admin (talk | contribs)
No edit summary
 
(10 intermediate revisions by 2 users not shown)
Line 3: Line 3:
| image          = File:6-1750_1997.jpg
| image          = File:6-1750_1997.jpg
| caption        =
| caption        =
| year            = 1997
| year            = {{Start date and age|1997|df=y}}
| manufacturer    = Pierce
| manufacturer    = Pierce
| apparatus_type  = Pumper
| apparatus_type  = Pumper
| previously      =
| previously      =
| subsequently    =
| subsequently    = Thomas Creek West Side Rural Engine 2221
| predecessor    = [[6-1002 (1972)|1972 Mack Pumper (6-1002)]]
| predecessor    = [[6-1002 (1972)|1972 Mack Pumper (6-1002)]]
| successor      =
| successor      = [[6-1750 (2019)|2019 Seagrave Pumper (6-1750)]]
}}
 
{{Infobox At-a-Glance
| model              = Lance II
| apparatus_subtype  =
| serial            = EA907
| cost              =
| aerial_vertical    =
| pump_capacity      = 1750 GPM
| water_capacity    = 1000 USG
| foam_capacity      = 30 USG
| delivery_date      = October 10, 1997
| inservice_date    =
| dedication_date    = May 30, 1998
| outservice_date    = December 23, 2019
}}
}}


Line 31: Line 46:
| raised_roof          = 12"
| raised_roof          = 12"
| bumper              = Extended with intake and preconnect
| bumper              = Extended with intake and preconnect
| cab_length          = 94"
| cab_length          = {{convert|94|in|ftin}} crew cab
| tilt                = Split
| tilt                = Split
| cab_features        =
| cab_features        =
Line 47: Line 62:
| pump_location      = Midship
| pump_location      = Midship
| pump_panel        =
| pump_panel        =
| pump_drive        = Driveshaft
| pump_drive        = Split-shaft
| water_capacity    = 1000 USG
| water_capacity    = 1000 USG
| foam_system        = Akron 3096, 95 GPM, 0-6%
| foam_system        = Akron 3096, 95 GPM, 0-6%
| foam_type          = Class B
| foam_type          = Class B
| foam_capacity      = 30
| foam_capacity      = 30 USG
| hose_reel          = 1 booster in rear compartment
| hose_reel          = 1 booster in rear compartment
| pump_features      =
| pump_features      =
Line 69: Line 84:
| cascade        =
| cascade        =
| misc_equipment =
| misc_equipment =
}}<!--{{Apparatus Dimensions
}}{{Apparatus Dimensions
| overall_height =
| overall_height = {{convert|115|in|ftin}}
| overall_length =
| overall_length = {{convert|402|in|ftin}}
| wheelbase      =
| wheelbase      = {{convert|119|in|ftin}}
}}-->{{Apparatus Construction
}}{{Apparatus Construction
| factory              = Appleton, WI
| factory              = Appleton, WI
| dealer                = Tyler Fire Equipment
| dealer                = Tyler Fire Equipment
Line 86: Line 101:
| inservice_date  =
| inservice_date  =
| dedication_date = May 30, 1998
| dedication_date = May 30, 1998
| outservice_date   =
| outservice_date = December 23, 2019
| purchaser      =
| purchaser      = Thomas Creek West Side Rural Fire Protection District (Lakeview, Oregon)
| sale_date      =
| sale_date      = January 28, 2020
| sale_price      =
| sale_price      =  
| misc_history    = Repainted by KME in November 2010
| misc_history    = Repainted by KME in November 2010
}}
}}
<youtube>Jsnj3Dn8txo</youtube>
<youtube>YTXx9_PcMDc</youtube>
<youtube>siB1gsk2ZkI</youtube>
<youtube>q__1Unts7Ag</youtube>
<youtube>ubWic8bHtfg</youtube>


{{Hillcrest_Apparatus_Navbox}}
{{Hillcrest_Apparatus_Navbox}}


[[Category:Active Apparatus]]
[[Category:Retired Apparatus]]
[[Category:1997]]
[[Category:1997]]
[[Category:Pierce]]
[[Category:Pierce]]
Line 103: Line 124:
[[Category:Tyler Fire Equipment]]
[[Category:Tyler Fire Equipment]]
[[Category:Hillcrest FD]]
[[Category:Hillcrest FD]]
[[Category:YouTube]]

Latest revision as of 01:12, 10 November 2021

6-1750
Overview
Year 1997; 27 years ago (1997)
Manufacturer Pierce
Type Pumper
Subsequently Thomas Creek West Side Rural Engine 2221
Chronology
Predecessor 1972 Mack Pumper (6-1002)
Successor 2019 Seagrave Pumper (6-1750)


At-a-Glance
Model Lance II
Serial Number EA907
Features
Pump Capacity 1750 GPM
Water Capacity 1000 USG
Foam Capacity 30 USG
Notable Dates
Delivery October 10, 1997
Dedication May 30, 1998
Out of Service December 23, 2019

General

  • Apparatus Type: Pumper
  • Manufacturer: Pierce
  • Year: 1997
  • Serial Number: EA907
  • VIN: 4P1CT02S5VA000670
  • Color: White over red
  • NIMS Resource Typing: Engine Type I
  • Dept. Designation: #3

Chassis/Cab

  • Model: Lance II
  • Cab Material: Aluminum
  • Crew Capacity: 7
  • Doors: 4
  • Raised Roof: 12"
  • Front Bumper: Extended with intake and preconnect
  • Length: 94 inches (7 ft 10 in) crew cab
  • Tilt: Split

Drivetrain

  • Propulsion: Diesel
  • Engine Make/Model: Detroit Diesel Series 60
  • Engine Specs: 12.7 L, 470 hp, 1550 lb-ft, Inline 6
  • Transmission Make/Model: Allison HD4060P
  • Transmission Specs: 5-speed automatic

Pump & Tank

  • Pump Make/Model: Waterous CMU
  • Pump Capacity: 1750 GPM, two-stage
  • Pump Location: Midship
  • Drive Type: Split-shaft
  • Water Capacity: 1000 USG
  • Foam System: Akron 3096, 95 GPM, 0-6%
  • Foam Type: Class B
  • Foam Capacity: 30 USG
  • Hose Reels: 1 booster in rear compartment

Body

  • Material: Aluminum

Equipment

  • Generator: Onan HDKAG 10kW diesel
  • Reels: 1 electrical

Dimensions

  • Overall Height: 115 inches (9 ft 7 in)
  • Overall Length: 402 inches (33 ft 6 in)
  • Wheelbase: 119 inches (9 ft 11 in)

Construction

  • Factory: Appleton, WI
  • Dealer: Tyler Fire Equipment
  • Delivery Date: October 10, 1997

Disposition

  • Dedication Date: May 30, 1998
  • Out of Service Date: December 23, 2019
  • Purchaser: Thomas Creek West Side Rural Fire Protection District (Lakeview, Oregon)
  • Sale Date: January 28, 2020
  • Misc. History: Repainted by KME in November 2010