25-1750 (1997): Difference between revisions
Jump to navigation
Jump to search
Other Admin (talk | contribs) m Text replacement - "| tank_capacity =" to "| water_capacity =" |
Other Admin (talk | contribs) No edit summary |
||
(5 intermediate revisions by 2 users not shown) | |||
Line 3: | Line 3: | ||
| image = File:25-1750_1997.jpg | | image = File:25-1750_1997.jpg | ||
| caption = | | caption = | ||
| year = 1997 | | year = {{Start date and age|1997|df=y}} | ||
| manufacturer = Pierce | | manufacturer = Pierce | ||
| apparatus_type = Pumper | | apparatus_type = Pumper | ||
Line 10: | Line 10: | ||
| predecessor = [[25-1000 (1976)|1976 Mack Pumper (25-1000)]] | | predecessor = [[25-1000 (1976)|1976 Mack Pumper (25-1000)]] | ||
| successor = | | successor = | ||
}} | |||
{{Infobox At-a-Glance | |||
| model = Lance II | |||
| apparatus_subtype = Rescue-Pumper | |||
| serial = EA524 | |||
| cost = | |||
| aerial_vertical = | |||
| pump_capacity = 1750 GPM | |||
| water_capacity = 1000 USG | |||
| foam_capacity = 50 USG | |||
| delivery_date = | |||
| inservice_date = | |||
| dedication_date = | |||
| outservice_date = | |||
}} | }} | ||
{{Apparatus General | {{Apparatus General | ||
| apparatus_type = Pumper | | apparatus_type = Pumper | ||
| apparatus_subtype = | | apparatus_subtype = Rescue-Pumper | ||
| manufacturer = Pierce | | manufacturer = Pierce | ||
| year = 1997 | | year = 1997 | ||
Line 33: | Line 48: | ||
| cab_length = <!--{{convert|###|in|ftin}} overall, -->{{convert|87|in|ftin}} crew cab | | cab_length = <!--{{convert|###|in|ftin}} overall, -->{{convert|87|in|ftin}} crew cab | ||
| tilt = Split | | tilt = Split | ||
| cab_features = | | cab_features = Onspot chains | ||
}}{{Apparatus Drivetrain | }}{{Apparatus Drivetrain | ||
| propulsion = Diesel | | propulsion = Diesel | ||
| engine = Detroit Diesel Series 60 | | engine = Detroit Diesel Series 60 | ||
| engine_specs = 12.7 L, 430 hp, | | engine_specs = 12.7 L, 430 hp, 1450 lb-ft, Inline 6 | ||
| transmission = Allison HD4060PR | | transmission = Allison HD4060PR | ||
| transmission_specs = 5-speed automatic | | transmission_specs = 5-speed automatic | ||
Line 43: | Line 58: | ||
| 4wd = | | 4wd = | ||
}}{{Apparatus Pump | }}{{Apparatus Pump | ||
| pump = Waterous | | pump = Waterous CMU | ||
| pump_capacity = 1750 GPM | | pump_capacity = 1750 GPM, two-stage | ||
| pump_location = Midship | | pump_location = Midship | ||
| pump_panel = Top | | pump_panel = Top | ||
| pump_drive = | | pump_drive = Split-shaft | ||
| water_capacity = 1000 USG | | water_capacity = 1000 USG | ||
| foam_system = Akron 3096, 95 GPM, 0-6% | | foam_system = Akron 3096, 95 GPM, 0-6% | ||
Line 57: | Line 72: | ||
| body_manufacturer = | | body_manufacturer = | ||
| body_type = | | body_type = | ||
| body_material = | | body_material = Aluminum | ||
| body_length = <!-- {{convert|###|in|ftin}} --> | | body_length = <!-- {{convert|###|in|ftin}} --> | ||
| body_features = | | body_features = | ||
}}{{Apparatus Equipment | }}{{Apparatus Equipment | ||
| generator = | | generator = Yes | ||
| light_tower = | | light_tower = Will-Burt Nightscan 15', horizontal articulating, 240 VAC, 4000w halogen | ||
| reels = | | reels = 1 electric | ||
| tool_power = | | tool_power = | ||
| compressor = | | compressor = | ||
Line 78: | Line 93: | ||
| cost = <!-- $6,500 ({{Inflation|US|6500|1931|fmt=eq}}) --> | | cost = <!-- $6,500 ({{Inflation|US|6500|1931|fmt=eq}}) --> | ||
| construction_started = | | construction_started = | ||
| construction_complete = | | construction_complete = May 1997 | ||
| delivery_date = | | delivery_date = | ||
| purchased_from = | | purchased_from = | ||
Line 92: | Line 107: | ||
| misc_history = | | misc_history = | ||
}} | }} | ||
<youtube>nAZrd1TlB4A</youtube> | |||
{{South_Spring_Valley_Apparatus_Navbox}} | {{South_Spring_Valley_Apparatus_Navbox}} | ||
Line 101: | Line 118: | ||
[[Category:Pierce Lance II]] | [[Category:Pierce Lance II]] | ||
[[Category:Pumper]] | [[Category:Pumper]] | ||
[[Category:Rescue-Pumper]] | |||
[[Category:Tyler Fire Equipment]] | [[Category:Tyler Fire Equipment]] | ||
[[Category:South Spring Valley FD]] | [[Category:South Spring Valley FD]] | ||
[[Category:YouTube]] |
Latest revision as of 02:11, 26 April 2019
25-1750 | |
---|---|
Overview | |
Year | 1997 |
Manufacturer | Pierce |
Type | Pumper |
Chronology | |
Predecessor | 1976 Mack Pumper (25-1000) |
At-a-Glance | |
---|---|
Model | Lance II |
Sub Type | Rescue-Pumper |
Serial Number | EA524 |
Features | |
Pump Capacity | 1750 GPM |
Water Capacity | 1000 USG |
Foam Capacity | 50 USG |
General
- Apparatus Type: Pumper
- Apparatus Sub Type: Rescue-Pumper
- Manufacturer: Pierce
- Year: 1997
- Serial Number: EA524
- VIN: 4P1CT02S1VA000391
- Color: White over red
- NIMS Resource Typing: Engine Type I
Chassis/Cab
- Model: Lance II
- Cab Material: Aluminum
- Doors: 4
- Raised Roof: 22"
- Length: 87 inches (7 ft 3 in) crew cab
- Tilt: Split
- Misc. Features: Onspot chains
Drivetrain
- Propulsion: Diesel
- Engine Make/Model: Detroit Diesel Series 60
- Engine Specs: 12.7 L, 430 hp, 1450 lb-ft, Inline 6
- Transmission Make/Model: Allison HD4060PR
- Transmission Specs: 5-speed automatic
Pump & Tank
- Pump Make/Model: Waterous CMU
- Pump Capacity: 1750 GPM, two-stage
- Pump Location: Midship
- Panel Location: Top
- Drive Type: Split-shaft
- Water Capacity: 1000 USG
- Foam System: Akron 3096, 95 GPM, 0-6%
- Foam Capacity: 50 USG
Body
- Material: Aluminum
Equipment
- Generator: Yes
- Light Tower: Will-Burt Nightscan 15', horizontal articulating, 240 VAC, 4000w halogen
- Reels: 1 electric
Dimensions
Construction
- Factory: Appleton, WI
- Dealer: Tyler Fire Equipment
- Construction Complete: May 1997
Disposition