10-1250 (1996): Difference between revisions
Jump to navigation
Jump to search
Other Admin (talk | contribs) mNo edit summary |
Other Admin (talk | contribs) m Text replacement - "= Drivetrain" to "= Split-shaft" |
||
Line 47: | Line 47: | ||
| pump_location = Midship | | pump_location = Midship | ||
| pump_panel = | | pump_panel = | ||
| pump_drive = | | pump_drive = Split-shaft | ||
| water_capacity = 750 USG | | water_capacity = 750 USG | ||
| foam_system = | | foam_system = |
Revision as of 11:45, 22 February 2018
10-1250 | |
---|---|
Overview | |
Year | 1996 |
Manufacturer | Pierce |
Type | Pumper |
Chronology | |
Predecessor | 1976 Seagrave Pumper (10-1250) |
General
- Apparatus Type: Pumper
- Manufacturer: Pierce
- Year: 1996
- Serial Number: E9800
- VIN: 4P1CT02P3TA000336
- Color: White over red
- NIMS Resource Typing: Engine Type I
Chassis/Cab
- Model: Dash
- Crew Capacity: 6
- Doors: 4
- Raised Roof: 8"
- Tilt: Full
- Misc. Features: Onspot chains
Drivetrain
- Propulsion: Diesel
- Engine Make/Model: Detroit Diesel 6V-92TA
- Engine Specs: 9.0 L, 300 hp, 957 lb-ft, V6
- Transmission Make/Model: Allison HD4060PR
- Transmission Specs: 5-speed automatic
Pump & Tank
- Pump Make/Model: Waterous CMU
- Pump Capacity: 1500 GPM, two-stage
- Pump Location: Midship
- Drive Type: Split-shaft
- Water Capacity: 750 USG
Body
Equipment
Dimensions
Construction
- Factory: Appleton, WI
- Dealer: Tyler Fire Equipment
Disposition